IAQ Detectors, the indoor air quality brand of Ace Instruments, manufactures CE certified temperature and relative humidity transmitters for commercial buildings, server rooms, and pharmaceutical storage. The range spans built-in probe, external probe, dew point, and duct-mounted configurations, with output via Modbus RS-485, 4-20mA, or 0-10V.
ASHRAE 55-2023 defines a year-round comfort target of 20-26°C and
40-60% relative humidity, while server room environments follow the wider ASHRAE Class A2 allowable range of 18-27°C and 20-80% RH.
Comfort range reference: ASHRAE 55-2023

T/RH Transmitter (Built-in Probe)

T/RH Transmitter (External Probe)

Dew Point Transmitter

Server Room Temperature Monitor
.webp)
Immersion Temperature Sensor

Duct Temperature / Humidity Monitor
Quick specification reference across the range
| Feature | T/RH Transmitter (Built-in Probe) | T/RH Transmitter (External Probe) | Dew Point Transmitter | Server Room Temperature Monitor | Immersion Temperature Sensor | Duct Temperature / Humidity Monitor |
|---|---|---|---|---|---|---|
| Mount type | Wall | Wall + remote probe | Wall | Wall | Immersion / probe | Duct |
| Temperature | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Humidity (RH) | ✓ | ✓ | ✓ | N/A | N/A | ✓ |
| Dew point calculation | N/A | N/A | ✓ | N/A | N/A | N/A |
| Modbus RS-485 | ✓ | ✓ | ✓ | ✓ | N/A | ✓ |
| Best for | General offices | Chambers, enclosures | Condensation-sensitive areas | Data centres | Liquid / process temperature | AHU, ductwork |
Where continuous temperature and humidity monitoring is critical
Commercial buildings
Open-plan offices monitor temperature and RH against ASHRAE 55-2023 comfort targets for occupant wellbeing.
Data centres & server rooms
Server room instruments track the ASHRAE Class A2 allowable range of 18-27°C and 20-80% RH to protect equipment uptime.
Hospitals & labs
Pharmaceutical GDP storage rooms hold 15-25°C and below 60% RH, continuously logged for compliance.
Museums
Collection storage maintains a stable 16-22°C and 45-55% RH per PAS 198:2012, with rate-of-change limited to 10% RH per 24 hours.
Educational institutions
Classrooms monitor temperature and humidity alongside CO2 as part of comprehensive comfort and IAQ programs.
Retail spaces
Retail environments maintain comfort-band temperature and humidity to support dwell time and product storage conditions.
Expert guidance
Our application engineers will recommend the right instrument based on your space type, probe requirements, and BMS integration. Most enquiries answered within 24 hours.